Fire Resistance

All FYFESTONE Blocks provide excellent protection against the
effects of fire.
Fire resistance of a masonry wall is taken to be the time
elapsed from the start of the test, to failure of stability,
integrity or thermal insulation. (30 minutes–6 hours)
Notional periods of the fire resistance for masonry walls to
comply with the building regulations are given in Table 14 of BS
5628: Part 3.
Relevant factors affecting the use of masonry units for fire
resistance purposes are as follows:
Designation of aggregates
Class 1 aggregates
Include limestone, aircooled blast furnace slag, foamed and
expanded slag, crushed brick, wellburnt clinker, expanded clay or
shale, sintered pulverised fuel ash and pumice.
Class 2 aggregates
Include all gravels and crushed natural stone, except
limestone.
Relevant factors affecting the use of Fyfestone units for fire
resistance are as follows:
- The function of the wall (load-bearing/non load-bearing)
- Wall construction - single leaf / cavity
- Width of the units
- Wall finish – plaster/plasterboard etc
The fire resistances quoted on the individual Fyfestone product
data sheets are based on:
- Made with class 1 or class 2 aggregate
- Load-bearing or non load-bearing
- Single leaf (cavity wall construction in bold font.)
- No finish
For alternative forms of construction, please contact the
Fyfestone technical advisory department on 01285 646800.
For panel walls which are to provide fire resistance where edge
isolation is necessary, special consideration should be given to
the edge details.
In walls designed to resist fire, any movement control joints
necessary should be fitted with a non-combustible material capable
of accepting the anticipated movement and sealed with an
appropriate material to give the same fire resistance as the
blockwork.
Fire Resistance Properties
For Architectural Masonry, Polished and Standard
(With Class 1 Aggregate as BS 5628 Part 3)
| PRODUCT |
LOAD-BEARING CAVITY WALL |
LOAD-BEARING SINGLE LEAF WALL |
NON-LOAD-BEARING CAVITY WALL |
NON-LOAD-BEARING SINGLE LEAF WALL |
| 65mm Solid |
1 Hour |
1 Hour |
4 Hours |
2 Hours |
| 90mm Solid |
6 Hour |
2 Hours |
6 Hour |
2 Hours |
| 100mm Solid |
6 Hour |
6 Hour |
6 Hour |
2 Hours |
| 140mm Solid |
6 Hour |
6 Hour |
6 Hour |
4 Hours |
| 190mm Solid |
6 Hour |
6 Hour |
6 Hour |
6 Hour |
| 215mm Solid |
6 Hour |
2 Hours |
6 Hour |
6 Hour |
| 140mm Hollow |
6 Hour |
2 Hours |
6 Hour |
3 Hours |
| 215mm Hollow |
6 Hour |
2 Hours |
6 Hour |
4 Hours |
| 100mm Cellular |
6 Hour |
2 Hours |
6 Hour |
2 Hours |
| 140mm Cellular |
6 Hour |
2 Hours |
6 Hour |
3 Hours |
NOTE: All the above products utilise Class 1
Aggregate.
The fire ratings shown can be as consistent for all Fyfestone
products with the same thickness as product description, providing
the product in question utilises a Class 1 Aggregate
(Limestone).
For further information on products utilising a Class 2
Aggregate (Granite etc.), please contact the Fyfestone technical
advisory department on 01285 646800.